John Deere code ECU 91.03 — Primary throttle input voltage above range
SPN 91 · FMI 3 · Controller ECU
What ECU 91.03 means for you
Diagnose soon: the affected function may not work correctly while the code is active.
Symptoms
- Code ECU 91.03 (also written ECU 000091.03) stored by the Engine Control Unit
- A warning may be shown on the machine display
Common causes
- Signal wire of the primary analog throttle circuit shorted to a supply or battery voltage
- Open ground or reference circuit for the primary analog throttle circuit
- Damaged, wet or corroded connector on the primary analog throttle circuit circuit
- Failed primary analog throttle circuit
Tune it yourself
Add John Deere machine tuning to your workshop. We supply the tools and the file, and you keep the profit.
Start tuningWhat this code means
The primary analog throttle input voltage rises above the sensor's upper limit, so the ECU treats the circuit as faulty (FMI 3, voltage above normal).
On John Deere skid steers: On skid steers this input is the hand throttle, hand throttle dial B18, whose circuit voltage reads above normal.
On John Deere tractors: On tractors the reading is outside its defined limits, the ECU substitutes an error value for the broadcast data, and a signal that stays high when commanded low also triggers it.
In SAE J1939 terms this is SPN 91, reported with failure mode identifier (FMI) 3: the circuit voltage is above normal, or the circuit is shorted to a higher voltage source. It is logged by the Engine Control Unit (ECU).
How a workshop diagnoses it
- Read all active and stored codes with a John Deere-compatible diagnostic tool and note related codes.
- Inspect the primary analog throttle circuit connector and harness for damage, moisture, corrosion or chafing.
- With a multimeter, check supply, ground and signal at the primary analog throttle circuit connector against the service specification.
- Check the circuit for shorts to ground or to voltage and for continuity back to the controller.
- Replace the primary analog throttle circuit only after the wiring checks pass, then clear the code and retest.
Frequently asked questions
The primary analog throttle input voltage rises above the sensor's upper limit, so the ECU treats the circuit as faulty (FMI 3, voltage above normal).
Severity: medium. Diagnose soon: the affected function may not work correctly while the code is active.
Our code list records it on John Deere skid steers and John Deere tractors. The exact meaning can depend on the machine and software level, so confirm with a diagnostic read.
No. A calibration does not repair the fault behind this code. Repair the primary analog throttle circuit issue and confirm no codes remain active before the ECU is read for tuning.